Revision 11 as of 2018-07-27 06:15:01

Clear message
Locked History Actions

Projectos/MuonTomography

Muon Tomography LIP wiki page

This is the Wiki of the Muon Tomography group. You need to register in Wiki and after that ask to be included in 'Wiki Muon Tomography Group' to be able to edit it. You should contact Sofia Andringa ou Lorenzo Cazon.

For any doubts just email Web Team of LIP CC ( webservices@lip.pt )


Project Overview

The muon tomography group puts together different expertises on particle detection, simulation and analysis and geophysics data analysis and interpretation, based in Coimbra, Évora and Lisboa.

Group Members and contact

Pilot Project at Lousal

A first goal is to install a RPC based Muon Telescope at the Lousal Ciência Viva center, and operate it remotely, 30 meters underground in a "non-operating" mine environment, and exposed to visitors and even some bats.

With this prototype we aim at mapping the gallery and accesses and, later, try to distinguish different rock types/densities around it. The primary location will be chosen to maximize the contrasts and features that we aim at identifying.

The muon data should be complemented by external information on topography, for example and will later be compared and combined with measurements by other methods. The final result should be obtained by common inversion of gravimetry and muography data.

Being at a Ciência Viva center, the detector should be accompanied by an explanation of what and how it is measuring muons and of the final goals of the project; if possible, the telescope should have some display of the data as it is collected. Ideally we'd join other displays, like a muon spark chamber.

General info on Lousal

Technical info on Lousal

Internal Information Repository

Initial project submitted to FCT;

The visit to Lousal;

Internal meetings.

External Information Repository

Seminars:

Seminar C. Carloganu (July 2018)

Papers: (where to store? how to organize?)

on muons and geophysics:

<https://drive.google.com/drive/folders/1R-UCA-ZTNeCqGCPfWA4R4oXJlEL10LzW?usp=sharing_eil&ts=5b34adb3>

mails Cazon 2018-05-08, 2017-02-02

mail JBorges 2017-04-30, 2017-02-03

Tomography of the Coimbra Building

There is a lot of data available from the detector test muon telescope at Coimbra.

Some pre-treated data is in: www.coimbra.lip.pt/~alberto/data.tar.gz with format:

  • ano, mes, dia, hora, minuto, segundo,

Posição longitudinal P1, P2, P3, P4, - diferença de tempo, escala de TDC bins

Posição transversal de P1, P2, P3, P4, - 1 de 15 strips de 30 mm (0.4 mm de intervalo)

Tempos do telescópio T1, T2, T3, T4, sem calibrar - média dos tempos, usada no trigger

As posições verticais são: P1=49.75 cm, P2=52.25 cm, P3=2.25 cm, P4=6.75cm.

Outras 128 variáveis de um detetor de Marta que esta por cima do telescópio a 143 cm. Este último não esta no trigger.

The master thesis of Vitor (USP-S.Carlos)

Technical information on RPC and DAQ



Links