Projectos/MuonTomography/UCoimbraProject

Tomography of LIP-Coimbra

Data acquisitions

For more details, check the logbook.

The data files are in these links.

MUTOM data acquisitions

Year

Duration

Trigger planes

Spacing (cm)

Localization

Orientation (deg)

Alignment

Gains

2020

01 Mar - 28 Mar

1&3

14.5

position 1, table

0

no info

default

01 Jun - 27 Jul

1&2

14.5

position 1, table

0

no info

default

27 Jul - 05 Sep

1&2

33.5

position 2, trolley

90

info

default

05 Sep - 30 Sep

1&2

33.5

open sky, trolley

0

info

default

30 Sep - 12 Nov

1&2

33.5

position 2, trolley

45

info

default

12 Nov - 22 Dec

1&2,2&3,1&3, corepix

33.5

position 2, trolley

45

info

default

2021

14 Jan - 30 Mar

1&2,2&3,1&3, corepix

33.5

position 2, trolley

45

info

gains1

30 Mar - 23 Apr

1&2,2&3,1&3, corepix

33.5

position 2, trolley

45

aligned

gains1

24 Apr - 14 May

1&2,2&3,1&3, corepix

33.5

position 2, trolley

45

aligned

gains2

14 May - 14 Jun

1&2,2&3,1&3, corepix

33.5

position 2, trolley

45

aligned

gains3

22 Jul - 14 Set

1&2,2&3,1&3, corepix

33.5

position 2, trolley

45

aligned

gains3

15 Set - 17 Nov

1&2,2&3,1&3, corepix

33.5

high contrast, trolley

0

aligned

gains3

20 Nov - 21 Dec

1&2,2&3,1&3, corepix

33.5

entrance 1, trolley

-90

aligned

gains3

2022

23 Dec - 23 Jan

1&2,2&3,1&3, corepix

33.5

entrance 2, trolley

-90

aligned

gains3

24 Jan - 4 Apr

1&2,2&3,1&3, corepix

33.5

entrance 2, trolley 15º

-90

aligned

gains3

5 Apr - 20 Apr

1&2,2&3,1&3, corepix

33.5

entrance 2, trolley 28.5º

-90

aligned

gains3

21 Apr - 26 Apr

1&2,2&3,1&3, corepix

33.5

entrance 3, trolley

-90

aligned

gains3

MUTOM data analysis

Year

Duration

MUTOM reports

Efficiency

Simulation

Maps

2020

01 Mar – 28 Mar

no info

E2 - 74 %

position 1

info

01 Jun – 27 Jul

no info

E3 – 83 %

position 2

info

27 Jul – 05 Sep

no info

E3 – 86 %

position 2, 90 deg

info

05 Sep – 30 Sep

no info

E3 – 82 %

open sky

info

30 Sep – 12 Nov

no info

E3 – 84 %

position 2, 45 deg

info

12 Nov – 22 Dec

no info

E1 – 87 % E2 – 84 % E3 – 87 %

position 2, 45 deg

info

2021

14 Jan – 30 Mar

no info

E1 – 89 % E2 – 86 % E3 – 91 %

position 2, 45 deg

info

30 Mar – 23 Apr

no info

E1 – % E2 – % E3 – %

position 2, 45 deg

no info

24 Apr – 14 May

no info

E1 – 88 % E2 – 82 % E3 – 87 %

position 2, 45 deg

info

14 May – 14 Jun

no info

E1 - 87 % E2 - 77 % E3 - 83 %

position 2, 45 deg

info

22 Jul – 14 Set

info

E1 – 87 % E2 – 73 % E3 – 84 %

position 2, 45 deg

info

15 Set – 17 Nov

info

E1 – 83 % E2 – 74 % E3 – 83 %

high contrast

info

20 Nov – 21 Dec

info

E1 – 95 % E2 – 79 % E3 – 90 %

entrance 1

info

2022

23 Dec – 23 Jan

info

E1 – 93 % E2 – 78 % E3 – 85 %

entrance 2

info

24 Jan – 4 Apr

info

E1 – 95% E2 – 79% E3 – 90 %

entrance 2, 15 deg (zenital)

info

5 Apr – 20 Apr

info

E1 – % E2 – % E3 – %

entrance 2, 28.5 deg (zenital)

info (print)

21 Apr – 26 Apr

info

E1 – % E2 – % E3 – %

entrance 3

no info

Notes:

  • spacing refers to the (approximate) distance between the RPC planes

  • orientation referes to the rotation angle of the RPC planes around the vertical, measured counterclockwise and relative to the orientation of the original position (in the original position, the front-end electronics side is next to the wall that separates the room B.24 from the rooms B.S3 and B.24.3)

  • the trolley inclination is towards the entrance door

2021 - 15 a 21 Jun - test self-trigger / cable change / gas recirculation

back to normal at 17h of July 20 (not clear the intermediate state)

Old data acquisitions

A RPC based Muon Telescope has been operating in the LIP-Coimbra detector laboratory for many years. It is used to test each new detector plane that is produced there. We can use the data also to image the building of the UCoimbra Physics department building.

There is a lot of data available from the detector test muon telescope at Coimbra.

This is a 2.0 m x 0.5 m x 0.5 m telescope, with 4 planes at Z=(2.25,6.75;49.75,52.25)cm.

The new detector planes are at 143 cm for testing, and do not participate in the trigger.

  • The data consists on (time, charge) x 2 ends x 15 strips x 4 RPC planes
  • The trigger is a coincidence, within 50 ns, of 1(/2) top and 1(/2) bottom signals
  • The event T0 is defined as the minimum of the times (T1) on the trigger side
  • The two top planes are 4 gap RPCs, the two lower are 10 gaps RPCs, sharing HV
  • Monitoring has 3 HV, 4 gas flux, 1 current + enviorment at test plane (8T, 1P, 1H)

Some pre-treated data is in: www.coimbra.lip.pt/~alberto/data.tar.gz with format:

  • Ano, mes, dia, hora, minuto, segundo,
  • Posição longitudinal P1, P2, P3, P4, - diferença de tempo, escala de TDC bins
  • Posição transversal de P1, P2, P3, P4, - 1 de 15 strips de 30 mm (0.4 mm de intervalo)
  • Tempos do P1, P2, P3, P4, sem calibrar - média dos tempos, usada no trigger
  • Outras 128 variáveis de um plano testado a 143 cm, que não esta no trigger.
  • A posição vertical é P1=49.75 cm, P2=52.25 cm, P3=2.25 cm, P4=6.75cm.

=> Good for practicing data cleaning, data reconstruction and imaging techniques

=> Good plans for master thesis, smaller student projects and cases for outreach

The master thesis of Vitor (USP-S.Carlos) is based on this data The PhD thesis project of João Saraiva, for general reference



Links